OPERATION AND PRINTER DRIVER CONTROLS
Section 3-2
Control Panel Functions
Emergency Stop
Depressing the Emergency Stop button instantly disconnects all AC power to the system. This button
should only be used in case of emergency. To reset the system after executing an E-stop, twist the red
button clockwise to release the button. Then, reset the main circuit breaker at the rear of the machine.
On / Off
When the main circuit breaker is switched on, pressing this button will initialize the system and enter the
ready state.
File Name
Indicates the file name presently loaded or in the process of being engraved.
Number of Copies
Indicates the number of times the file name displayed has been engraved.
Open Interlock Indicator
A visible RED dot indicates an open interlock (door or panel).
Cycle Time
The amount of time displayed in minutes and seconds to complete one engraving cycle.
Display Screen
The display shows file and system information, provides access to the system controls.
Quit / Zoom
While mark file is visible on display, press to zoom, while in menus, press once will allow you to exit.
XY/Z Manual Motion
The motion button provides access for manual movement of the axes.
Camera / Auto Focus
Pushed once this button will turn on the camera, pushed a second time will allow Auto Focusing of the Z-
axis.
Select
Press once to confirm a choice in any menu.
Start Mark
Starts laser processing of the file displayed on the Display Screen.
Direction / Scroll Keys
These keys serve to control manual motion of the axes when used in conjunction with the XY/Z button.
They also can be used to scroll through the Display menu.
Pause / Resume
If a file is running, the Pause button halts the file execution and the focus carriage will move back to the
home position in the upper right corner of the engraving field. Press Pause a second time will resume the
file from the last point processed.